Bühlmann ZH-L16C-1a 2002 with GRADIENT FACTOR decompression:
* GF_low (CF32) = 30 %
* GF_high (CF33) = 90 %
* deco offset (CF16) = 1.0 m
* last stop (CF29) = 6 m
* dive started at Pamb = 1013 mbar
* Gas switch delay (CF55) = 0 min
CCR mode:
* Setpoint1: 1.3
* Diluant gas#1 = 21/0
* Bailout gas#2 = 32/0 at 40 m
0:00 40.0m DESCENT DONE
...
30:04 40.0m Deco:
40 m |
30 ' |
31 ' |
SP 1.30 |
12 m |
2 ' |
35 ' |
|
9 m |
2 ' |
38 ' |
|
6 m |
11 ' |
49 ' |
|
0 m |
---- |
50 ' |
TTS = 20 '
CNS = 28%
==== BAIL-OUT runtime ====
30:04 40.0m Deco:
40 m |
30 ' |
30 ' |
SP 1.30 |
40 m |
---- |
30 ' |
BAILOUT Gas#2 |
15 m |
1 ' |
34 ' |
|
12 m |
2 ' |
36 ' |
|
9 m |
4 ' |
41 ' |
|
6 m |
26 ' |
67 ' |
|
0 m |
---- |
68 ' |
TTS = 38 '
CNS = 18%
Depth = 40 m
Bottom time = 30 min
Bottom gas consumption (CF56) = 20 l/min
Ascent gas consumption (CF57) = 20 l/min
Gas#2 ( 32/00) = 1362