Bühlmann ZH-L16C-1a 2002 with GRADIENT FACTOR decompression:
* GF_low (CF32) = 20 %
* GF_high (CF33) = 75 %
* deco offset (CF16) = 1.0 m
* last stop (CF29) = 3 m
* dive started at Pamb = 1013 mbar
* Gas switch delay (CF55) = 0 min
OC gas list:
* First gas#3 = 16/50
* Deco gas#1 = 50/0 at 21 m
* Deco gas#4 = 36/0 at 33 m
* Deco gas#5 = 80/0 at 9 m
0:00 90.0m DESCENT DONE ppO2=1.60
...
20:04 90.0m Deco: ppO2=1.60 CNS=45%
90 m |
20 ' |
21 ' |
Gas#3 |
51 m |
1 ' |
25 ' |
|
48 m |
1 ' |
27 ' |
|
45 m |
2 ' |
29 ' |
|
42 m |
1 ' |
30 ' |
|
39 m |
2 ' |
33 ' |
|
36 m |
3 ' |
36 ' |
|
33 m |
1 ' |
37 ' |
SWITCH Gas#3 -> Gas#4 |
30 m |
2 ' |
40 ' |
|
27 m |
2 ' |
42 ' |
|
24 m |
2 ' |
44 ' |
|
21 m |
4 ' |
48 ' |
SWITCH Gas#4 -> Gas#1 |
18 m |
3 ' |
52 ' |
|
15 m |
6 ' |
58 ' |
|
12 m |
9 ' |
67 ' |
|
9 m |
10 ' |
78 ' |
SWITCH Gas#1 -> Gas#5 |
6 m |
16 ' |
94 ' |
|
3 m |
33 ' |
127 ' |
|
0 m |
---- |
128 ' |
TTS = 108 '
CNS = 118%
==== OC Runtime ====
20:04 90.0m Deco: ppO2=1.60 CNS=45%
90 m |
20 ' |
20 ' |
Gas#3 |
51 m |
1 ' |
25 ' |
|
48 m |
1 ' |
27 ' |
|
45 m |
2 ' |
29 ' |
|
42 m |
1 ' |
30 ' |
|
39 m |
3 ' |
34 ' |
|
36 m |
2 ' |
36 ' |
|
33 m |
1 ' |
37 ' |
SWITCH Gas#3 -> Gas#4 |
30 m |
2 ' |
39 ' |
|
27 m |
2 ' |
42 ' |
|
24 m |
3 ' |
45 ' |
|
21 m |
3 ' |
48 ' |
SWITCH Gas#4 -> Gas#1 |
18 m |
4 ' |
53 ' |
|
15 m |
6 ' |
59 ' |
|
12 m |
8 ' |
67 ' |
|
9 m |
11 ' |
79 ' |
SWITCH Gas#1 -> Gas#5 |
6 m |
16 ' |
95 ' |
|
3 m |
33 ' |
128 ' |
|
0 m |
---- |
129 ' |
TTS = 109 '
CNS = 119%
Depth = 90 m
Bottom time = 20 min
Bottom gas consumption (CF56) = 20 l/min
Ascent gas consumption (CF57) = 20 l/min
Gas#1 ( 50/00) = 1122
Gas#3 ( 16/50) = 5855
Gas#4 ( 36/00) = 687
Gas#5 ( 80/00) = 1814